索引于
  • Genamics 期刊搜索
  • 期刊目录
  • 引用因子
  • 乌尔里希的期刊目录
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • 期刊摘要索引目录
  • OCLC-WorldCat
  • 普布隆斯
  • 日内瓦医学教育与研究基金会
  • 欧洲酒吧
  • 谷歌学术
分享此页面
期刊传单
Flyer image

抽象的

Evaluation Of The Deformations On The Jaw Bone Due To A Band And Loop, Nance Appliance And Trans-Palatal Arch Space-Maintainers: A Three-Dimensional Finite Element Analysis

Uddanwadiker R*,Patil PG

In cases where the loss of a primary tooth is unavoidable and the child is at a development stage it is important to preserve the remaining space by a space-maintainer. To evaluate the response and characteristic behavior of three different space-maintainers (band and loop, Nance appliance, and Trans-palatal arch) subjected to masticatory forces with 3D Finite Element Analysis is a three dimensional digital solid model was prepared with a Solid Edge V20 software. The ANSYS Workbenchsoftware was used in conjunction with Solid Edge V20 to simulate the behavior of the objects (teeth and the devices) under structural loading conditions. The forces and constraints are applied in appropriate magnitude and direction. The Von mises stresses, strains and deformation were derived for all three designs and jaw without device. Range of deformation for band and loop is 0 to 4.6292e-6, for Nance-appliance is 0 to 3.7612e-6 and for trans-palatal arch is 0 to 3.7666e-6. The deformation range for the model without the appliance is 0 to 4.9676e-6. The finite element analysis shows that, the Nance appliance shows the least deformation among all the three selected designs.