索引于
  • 学术期刊数据库
  • 打开 J 门
  • Genamics 期刊搜索
  • 学术钥匙
  • 期刊目录
  • 中国知网(CNKI)
  • 引用因子
  • 西马戈
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-WorldCat
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 米亚尔
  • 大学教育资助委员会
  • 日内瓦医学教育与研究基金会
  • 欧洲酒吧
  • 谷歌学术
分享此页面
期刊传单
Flyer image

抽象的

The Pharmacokinetics of Fluticasone Furoate and Vilanterol Following Single Inhaled Administration in Combination and Intravenous Administration of Individual Components in Healthy Subjects

Ann Allen, Ludovic Apoux, Jo Bal, Joseph Bianco, Alison Moore, Ramiya Ravindranath, Lee Tombs and Rodger D Kempsford

Fluticasone furoate (FF)/vilanterol (VI), a novel inhaled corticosteroid/long-acting β 2 -agonist combination, is being developed as a once-daily inhaled treatment for asthma and chronic obstructive pulmonary disease. The two studies described here assess FF dose proportionality and VI equivalence across the clinical strengths of FF/ VI and the absolute bioavailability of the components administered as FF/VI in combination via the dry powder inhaler (DPI) intended for commercial use. Study 1 (NCT01213849) was a randomized, open-label, three-way crossover, single- dose study in healthy subjects designed to assess whether the systemic exposure of FF increased proportionately and VI systemic exposure was constant across different strength combinations of FF/VI (four inhalations of FF/ VI; 50/25 μg, 100/25 μg and 200/25 μg). Study 2 (NCT01299558) was an open-label, non-randomized, three- way crossover, single-dose study in healthy subjects conducted to determine the absolute bioavailability of FF/VI inhalation powder. Both FF and VI have high plasma clearance and extensive distribution into tissues. Overall, FF systemic exposure, as measured by AUC (0–t’) , was dose proportional over the 200-800 μg FF dose range. The less than dose proportional increase seen for FF C max is likely due to rate limited absorption from the lung. FF acts topically in the lung, whilst systemic exposure is related to safety. Consequently, the lack of dose proportionality for FF C max would be considered not to impact efficacy. Equivalence of VI exposure across the three FF/VI dosage strengths was demonstrated for AUC (0–t’) and C max . Following a single inhaled dose of FF/VI administered via DPI the absolute bioavailabilities of FF and VI were estimated to be 15% (90% confidence interval [CI]: 13%, 18%) and 27% (90% CI: 22%, 35%), respectively. FF showed longer retention in the lung than VI following inhaled administration, with the time for 90% of the total to be absorbed from the lung being on average 35.2 hours and 3.8 hours, respectively.