索引于
  • 学术期刊数据库
  • 打开 J 门
  • Genamics 期刊搜索
  • 学术钥匙
  • 期刊目录
  • 中国知网(CNKI)
  • 引用因子
  • 西马戈
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-WorldCat
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 米亚尔
  • 大学教育资助委员会
  • 日内瓦医学教育与研究基金会
  • 欧洲酒吧
  • 谷歌学术
分享此页面
期刊传单
Flyer image

抽象的

Accurate Method of HPLC-Ms/Ms Determination of Mycophenolic Acid in Human Plasma

Khokhlov AL, Yaichkov II, Shitov LN, Dzhurko YA, Shitova AM, Ryska M, Kubeš V, Shabrov VN and Miroshnikov AE

A simple, accurate and precise method was developed using HPLC-MS/MS to quantify mycophenolic acid in human plasma. Mycophenolic acid-D3 was used as internal standard. Sample preparation involved protein precipitation. Chromatographic analysis was performed on a Phenomenex Kinetex C18 (30 mm × 4.6 mm, 2.6 μm) column using acetonitrile-water as the mobile phase. Detection in negative ionization mode was used to quantify mycophenolic acid by multiple reaction monitoring. The calibration curve was linear in the range of 0.5-30 μg/mL, with intra-and inter-batch values for accuracy and precision (coefficient of variation) ranging from 99.76 to 111.38% and from 2.54 to 9.01%, respectively. The method was successfully applied to conduct a pharmacokinetic study of 360 mg coated tablet "Myfortic" in 48 healthy participants; 768 blood samples were analysed.

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证