索引于
  • 打开 J 门
  • Genamics 期刊搜索
  • 学术钥匙
  • 期刊目录
  • 全球影响因子 (GIF)
  • 中国知网(CNKI)
  • 乌尔里希的期刊目录
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-WorldCat
  • 普布隆斯
  • 日内瓦医学教育与研究基金会
  • 欧洲酒吧
  • 谷歌学术
分享此页面
期刊传单
Flyer image

抽象的

Potentiometric Sensor for Determination of Tramadol Hydrochloride in Pharmaceutical Preparations and Biological Fluids

Hazem M. Abu Shawish, Ayoub R. Al-Dalou, Nasser Abu Ghalwa and Anwar A. Abou Assi

A potentiometric tramadol-selective electrode based on the ion-association of tramadol hydrochloride (TDCl) with phosphomolybdic acid (TD-PM) is developed. The electrode exhibits a Nernstian slope of 58.3±0.7 mV/decade for tramadol ions in the concentration range 2.0 × 10 -6 - 1.0 × 10 -1 M with the limit of detection of 1.3 × 10 -6 M. The electrode has a fast and stable response time 5-8 s, good reproducibility and it can be used in pH range of 1.8-6.1. The present electrode show good discrimination of tramadol hydrochloride from several inorganic, organic ions, sugars and some common drug excipients. These characteristics of the electrode enable it to be used successfully for determination of tramadol hydrochloride in its pharmaceutical preparations and biological fl uids (urine and milk).