索引于
  • 打开 J 门
  • Genamics 期刊搜索
  • 引用因子
  • 宇宙IF
  • 西马戈
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • 期刊摘要索引目录
  • OCLC-WorldCat
  • 普罗奎斯特传票
  • 学者指导
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 日内瓦医学教育与研究基金会
  • 谷歌学术
分享此页面
期刊传单
Flyer image

抽象的

Real-time OCT for study of cornea of living Indian frogs and toads

Kumari S*, Nirala AK

A high-speed Optical Coherence Tomography (OCT) system based on single mode fiber which can capture eight images per second was used to acquire OCT images of the eyes of Indian frogs and toads. The axial resolution of the set up was estimated to be 18 m. With these OCT images, the ocular parameters, viz. corneal thickness, anterior chamber depth and anterior chamber angle were estimated. The thickness of the cornea of frog and toad is found to be 136.12 m and 100.66 m respectively. Measurement of corneal thickness is needed in many physiological and clinical studies and is helpful in diagnosis of several corneal disorders.