抽象的

Vaccine Adverse Event Reporting System

Tom T. Shimabukuro

The Vaccine Adverse Event Reporting System (VAERS) is a United States program for vaccine safety, co-managed by the U.S. Centers for Disease Control and Prevention (CDC) and the Food and Drug Administration (FDA). VAERS is a postmarketing surveillance program, collecting information about adverse events (possible harmful side effects) that occur after administration of vaccines to ascertain whether the risk–benefit ratio is high enough to justify continued use of any particular vaccine. VAERS, the Vaccine Safety Datalink, and the Clinical Immunization Safety Assessment (CISA) Network are tools by which the CDC and FDA monitor vaccine safety to fulfill their duty as regulatory agencies charged with protecting the public. VAERS has limitations, including unverified reports, misattribution, underreporting, and inconsistent data quality. CDC cautions that it is generally not possible to find out from VAERS data if a vaccine caused the adverse event, or how common the event might be.

VAERS has demonstrated its public health importance by providing health scientists with signals about possible adverse events following immunization. In one instance, VAERS detected reports for intussusception over that what would be expected to occur by chance alone after the RotaShield rotavirus vaccine in 1999. Epidemiologic studies confirmed an increased risk, and these data contributed to the product's removal from the US market. In another example, VAERS determined that there may be a potential for a small increase in risk for Guillain-Barre' syndrome (GBS) after the meningococcal conjugate vaccine, Menactra. As a result of this finding, a history of GBS became a contraindication to the vaccine and further controlled studies are currently underway to research this issue. Operation Each year the VAERS receives at least 50,000 reports of adverse events following immunization by more than 10 million vaccines. Higher-priority uses of the data include reports of death and other serious adverse events, recognizing and detecting adverse effects, and finding unexpected adverse events involving new vaccines. The VAERS data are also used to monitor known reactions to vaccines and for vaccine lot surveillance. Data mining techniques such as empirical Bayes methods can be used to improve the quality of data analysis.